Yokogawa EJX110A-JMS5G-917EN/SU22/D4/C1/M01/T13/GS+HDS5FRCMLME12ATEQ1 Pressure Transmitter w/ Alloy C-276, ATEX/FM Certified – Factory Price, Ready to Ship

EJX110A-JMS5G-917EN/SU22/D4/C1/M01/T13/GS+HDS5FRCMLME12ATEQ1

The Yokogawa EJX110A-JMS5G-917EN/SU22/D4/C1/M01/T13/GS+HDS5FRCMLME12ATEQ1 is a highly reliable pressure transmitter featuring 4 to 20 mA DC with digital communication (HART 5/HART 7), designed for demanding industrial applications.

★★★ Gold-Tier Yokogawa Supplier in China

  • Check Mark 100% Genuine & Brand New
  • Check Mark Global Fast Shipping via DHL/FedEx
  • Check Mark Fast Quotation within 12 Hours
  • Check Mark 1-Year Warranty Guaranteed
SKU: EJX110A-JMS5G-917EN/SU22/D4/C1/M01/T13/GS+HDS5FRCMLME12ATEQ1 Categories: , ,

Product Overview

The Yokogawa EJX110A-JMS5G-917EN/SU22/D4/C1/M01/T13/GS+HDS5FRCMLME12ATEQ1 is a high-performance differential pressure transmitter engineered for precision measurement in demanding industrial processes. Designed to deliver a 4 to 20 mA DC output with digital communication via HART 5 or HART 7, this instrument ensures seamless integration into existing distributed control systems (DCS) and asset management platforms. With a measurement range spanning 1 to 100 kPa (4 to 400 inH2O), it is ideally suited for flow, level, and pressure applications in oil and gas, chemical, and power generation sectors. The robust construction, featuring 316L SST or Hastelloy wetted parts, guarantees long-term reliability in corrosive or high-temperature environments, making it a cornerstone for operational integrity.

Key Features & High-End Benefits

This transmitter incorporates Yokogawa’s advanced silicon resonant sensor technology, delivering exceptional accuracy of ±0.04% of span and long-term stability that minimizes recalibration cycles. The multi-variable capability, enabled by HART 7 protocol, allows simultaneous transmission of differential pressure, static pressure, and process temperature, facilitating comprehensive process optimization without additional hardware. The all-welded diaphragm construction, available in Hastelloy C-276, provides superior resistance to hydrogen sulfide and chloride-induced stress corrosion cracking, ensuring uninterrupted operation in harsh upstream environments. Additionally, the local parameter setting (LPS) feature allows for on-site configuration without a communicator, reducing downtime during maintenance. The integral surge protection (SU22) and advanced diagnostics for plugging and impulse line blockage detection enhance predictive maintenance strategies, directly lowering total cost of ownership.

Industrial Excellence

Yokogawa’s EJ

Full Configuration Details

Complete Ordering Code:
EJX110A-JMS5G-917EN/SU22/D4/C1/M01/T13/GS+HDS5FRCMLME12ATEQ1
Transmitter Main Body - EJX110A-JMS5G-917EN
EJX110A
Main Model
Differential Pressure
-J
Output Signal
4 to 20 mA DC with digital communication (HART 5/HART 7)
M
Measurement Span
1 to 100 kPa (4 to 400 inH2O)
S
Wetted Parts Material
ASTM CF-8M / Hastelloy C-276
5
Process Connections
Process Connections
G
Bolts & Nuts
Bolts and Nuts
-9
Installation
Installation Style
1
Housing
Cast aluminum alloy
7
Electrical Connection
Electrical Connection
E
Integral Indicator
Integral Indicator
N
Mounting Bracket
Mounting Bracket
Optionals - /SU22/D4/C1/M01/T13/GSHDS5FRCMLME12ATEQ1
/SU22
Product Certifications
IECEx Intrinsically safe and SF22
/D4
Calibration
Calibration in kgf/cm2
/C1
Software And Diagnostics
Failure alarm down-scale
/M01
Material And Quality Certificates
Mill Certificate Cover flange
/T13
Calibration
Test Certificate for Pressure Test
/GS
Process Connections And Wetted Parts
Gold-plated 316L SST capsule gasket
HDS
Accessory Model
Diaphragm Seal System
5
Configuration
Double seal (High and Low side seals)
F
Capillary Connection
Process cover flange connection
RC
Flange Rating
ANSI Class 150 RF or similar
ML
Flange Size
2-inch or 3-inch flange
ME
Diaphragm Material
316L SST or Hastelloy
12
Capillary Length
Capillary length (e.g. 12 ft/m)
A
Fill Fluid
Silicone Fill Fluid
TEQ1
Special Specs
Special Specifications

Engineering Dimensions

Reliable Partnership with GT-EXIM

As an established industrial supplier, GT-EXIM ensures your procurement efficiency. We leverage our robust supply chain and large-scale stock inventory to offer highly competitive factory pricing and minimized lead times. Every unit supplied is 100% genuine and brand new, packed with heavy-duty export reinforcement to guarantee safe delivery globally. Partner with us for a streamlined, risk-free sourcing experience.

Ready to Start Your Project?

Contact us for a formal quotation and technical data confirmation.

📧 Email: sales@gt-exim.com
💬 WhatsApp: +86 17719526488

Full Configuration Details

Complete Ordering Code:
EJX110A-JMS5G-917EN/SU22/D4/C1/M01/T13/GS+HDS5FRCMLME12ATEQ1
Transmitter Main Body - EJX110A-JMS5G-917EN
EJX110A
Main Model
Differential Pressure
-J
Output Signal
4 to 20 mA DC with digital communication (HART 5/HART 7)
M
Measurement Span
1 to 100 kPa (4 to 400 inH2O)
S
Wetted Parts Material
ASTM CF-8M / Hastelloy C-276
5
Process Connections
Process Connections
G
Bolts & Nuts
Bolts and Nuts
-9
Installation
Installation Style
1
Housing
Cast aluminum alloy
7
Electrical Connection
Electrical Connection
E
Integral Indicator
Integral Indicator
N
Mounting Bracket
Mounting Bracket
Optionals - /SU22/D4/C1/M01/T13/GSHDS5FRCMLME12ATEQ1
/SU22
Product Certifications
IECEx Intrinsically safe and SF22
/D4
Calibration
Calibration in kgf/cm2
/C1
Software And Diagnostics
Failure alarm down-scale
/M01
Material And Quality Certificates
Mill Certificate Cover flange
/T13
Calibration
Test Certificate for Pressure Test
/GS
Process Connections And Wetted Parts
Gold-plated 316L SST capsule gasket
HDS
Accessory Model
Diaphragm Seal System
5
Configuration
Double seal (High and Low side seals)
F
Capillary Connection
Process cover flange connection
RC
Flange Rating
ANSI Class 150 RF or similar
ML
Flange Size
2-inch or 3-inch flange
ME
Diaphragm Material
316L SST or Hastelloy
12
Capillary Length
Capillary length (e.g. 12 ft/m)
A
Fill Fluid
Silicone Fill Fluid
TEQ1
Special Specs
Special Specifications

Documents

Manuals: