Rosemount 3051CFPDF005R6H0010D33MMIA01B9 Integral Orifice Flow Meter | Alloy C-276, Integral Manifold | China Supplier | Fast Delivery

3051CFPDF005R6H0010D33MMIA01B9

The Rosemount 3051CFPDF005R6H0010D33MMIA01B9 integral orifice flow meter ensures accurate process control with its Low-power, 1–5 Vdc with digital signal based on HART Protocol and proven performance architecture.

★★★ Gold-Tier Rosemount Supplier in China

  • 复选标记 100% Genuine & Brand New
  • 复选标记 Global Fast Shipping via DHL/FedEx
  • 复选标记 Fast Quotation within 12 Hours
  • 复选标记 1-Year Warranty Guaranteed

Product Overview

The Rosemount 3051CFPDF005R6H0010D33MMIA01B9 represents a pinnacle in precision flow measurement for demanding industrial process environments. As an integral orifice flow meter, this device combines the proven differential pressure (DP) measurement technology of the 3051 series with a factory-mounted, primary element assembly, eliminating field installation variables. Engineered for low-power applications, it provides a 1–5 Vdc output signal overlaid with a digital HART Protocol signal, enabling seamless integration into distributed control systems (DCS) and remote terminal units (RTUs). With a robust stainless steel (SST) construction and G½ process connection, this unit is designed to maintain operational integrity in corrosive or high-pressure loops. The calibrated measurement range of 0 to 1000 inH₂O (0 to 2.49 bar) makes it ideally suited for custody transfer, steam flow, and critical liquid or gas metering where repeatable accuracy is non-negotiable.

Key Features & High-End Benefits

Low-Power HART Communication: The 1–5 Vdc output with digital HART Protocol allows for direct interface with low-power logic controllers and battery-powered telemetry systems. This reduces the total cost of ownership by eliminating the need for external signal conditioners or high-voltage power supplies in remote locations. The digital signal provides real-time diagnostics and multi-variable data, enabling predictive maintenance scheduling that minimizes unplanned downtime.

Integral Orifice Assembly: By integrating the primary element (orifice plate) with the transmitter, this model eliminates potential leak paths and alignment errors associated with traditional impulse piping. The result is a 30–50% reduction in installation time and a significant improvement in long-term measurement stability. This configuration also reduces the risk of plugging in dirty services, enhancing

Full Configuration Details

Complete Ordering Code:
3051CFPDF005R6H0010D33MMIA01B9
Transmitter Main Body - 3051CFPDF005R6H0010D33MMI
3051CFP
Product Series
Integral Orifice Flow Meter
D
measurement_type
Differential pressure
F
material_type_and_body
316 SST, enhanced support body
005
line_size
½ in. (15 mm)
R6
process_connection
Pipe ends: flanged, Class 600 RTJ ASME B16.5, slip-on
H
orifice_plate_material
Alloy C-276
0010
bore_size_option
0.010 in. (0.25 mm) for ½ inch pipe
D3
transmitter_connection_platform
Direct-mount, 3-valve manifold, SST
3
differential_pressure_range
0 - 1000 inH2O (0 to 2.49 bar)
M
transmitter_output
Low-power, 1–5 Vdc with digital signal based on HART Protocol
M
housing_material
SST / G½
I
transmitter_performance_class
Up to ±1.75% flow rate accuracy
Optionals - A01B9
A01
Comprehensive Options
FOUNDATION™ Fieldbus control function block suite
B9
Mounting Brackets
B3 bracket with Series 300 SST bolts

Engineering Dimensions

Reliable Partnership with GT-EXIM

As an established industrial supplier, GT-EXIM ensures your procurement efficiency. We leverage our robust supply chain and large-scale stock inventory to offer highly competitive factory pricing and minimized lead times. Every unit supplied is 100% genuine and brand new, packed with heavy-duty export reinforcement to guarantee safe delivery globally. Partner with us for a streamlined, risk-free sourcing experience.

Ready to Start Your Project?

Contact us for a formal quotation and technical data confirmation.

📧 Email: sales@gt-exim.com
💬 WhatsApp: +86 17719526488

Full Configuration Details

Complete Ordering Code:
3051CFPDF005R6H0010D33MMIA01B9
Transmitter Main Body - 3051CFPDF005R6H0010D33MMI
3051CFP
Product Series
Integral Orifice Flow Meter
D
measurement_type
Differential pressure
F
material_type_and_body
316 SST, enhanced support body
005
line_size
½ in. (15 mm)
R6
process_connection
Pipe ends: flanged, Class 600 RTJ ASME B16.5, slip-on
H
orifice_plate_material
Alloy C-276
0010
bore_size_option
0.010 in. (0.25 mm) for ½ inch pipe
D3
transmitter_connection_platform
Direct-mount, 3-valve manifold, SST
3
differential_pressure_range
0 - 1000 inH2O (0 to 2.49 bar)
M
transmitter_output
Low-power, 1–5 Vdc with digital signal based on HART Protocol
M
housing_material
SST / G½
I
transmitter_performance_class
Up to ±1.75% flow rate accuracy
Optionals - A01B9
A01
Comprehensive Options
FOUNDATION™ Fieldbus control function block suite
B9
Mounting Brackets
B3 bracket with Series 300 SST bolts

Documents