Rosemount 3051CD3F22A1BS1M5DFI1Q4+1199WDAB3AEFWK1DB80 Remote Diaphragm Seal, LCD Display, ATEX/FM Certified, Bulk Price, Ready to Ship

3051CD3F22A1BS1M5DFI1Q4+1199WDAB3AEFWK1DB80

The Rosemount 3051CD3F22A1BS1M5DFI1Q4+1199WDAB3AEFWK1DB80 remote diaphragm seal ensures accurate process control with its FOUNDATION™ Fieldbus Protocol and proven performance architecture.

★★★ Gold-Tier Rosemount Supplier in China

  • 复选标记 100% Genuine & Brand New
  • 复选标记 Global Fast Shipping via DHL/FedEx
  • 复选标记 Fast Quotation within 12 Hours
  • 复选标记 1-Year Warranty Guaranteed
SKU: 3051CD3F22A1BS1M5DFI1Q4+1199WDAB3AEFWK1DB80 分类: , , 标签: ,

Product Overview

The Rosemount 3051CD3F22A1BS1M5DFI1Q4+1199WDAB3AEFWK1DB80 represents the pinnacle of differential pressure measurement for demanding process environments. This integrated Remote Diaphragm Seal (RDS) system combines the proven performance of the 3051C Coplanar™ pressure transmitter with a high-performance 1199 diaphragm seal assembly. Engineered for critical applications, this configuration delivers precise, stable measurements from -1000 to +1000 inH2O (-2.48 to +2.48 bar) for differential pressure (3051CD/CG) and 0 to 800 psia (0 to 55.15 bar) for absolute pressure (3051CA). The use of FOUNDATION™ Fieldbus protocol ensures seamless digital integration into modern Distributed Control Systems (DCS), enabling advanced diagnostics and asset management capabilities. With all wetted parts constructed from Alloy C-276, this system is specifically designed to withstand highly corrosive media, extreme temperatures, and aggressive chemical environments where standard stainless steel solutions would fail.

Key Features & High-End Benefits

**FOUNDATION™ Fieldbus Digital Integration** – The native FOUNDATION Fieldbus output provides deterministic, high-speed communication with your control network. This enables real-time access to multivariable data (pressure, temperature, and diagnostics) without additional wiring, reducing installation costs by up to 40% in greenfield projects. The protocol’s Link Active Scheduler (LAS) functionality ensures synchronized process data for critical loop control, enhancing overall process optimization.

**Alloy C-276 (Hastelloy C-276) Wetted Materials** – The 3051CD3F22A1BS1M5DFI1Q4 transmitter and 1199WDAB3AEFWK1DB80 seal system are fully wetted with

Full Configuration Details

Complete Ordering Code:
3051CD3F22A1BS1M5DFI1Q4+1199WDAB3AEFWK1DB80
Transmitter Main Body - 3051CD3F22A1B
3051C
Product Series
Coplanar Pressure Transmitter (Differential, Gage, or Absolute)
D
measurement_type
Differential
3
pressure_ranges
-1000 to +1000 inH2O (-2.48 to +2.48 bar) [3051CD/CG]; 0 to 800 psia (0 to 55.15 bar) [3051CA]
F
transmitter_output
FOUNDATION™ Fieldbus Protocol
2
transmitter_flange_type_and_material
Coplanar / SST / SST
2
isolating_diaphragm
316L SST
A
o_ring
Glass-filled PTFE
1
sensor_fill_fluid
Silicone
B
housing_material
Aluminum / M20 x 1.5
Optionals - S1M5DFI1Q4
S1
Ancillary Assemblies
Assemble to one Rosemount 1199 diaphragm seal
M5
Display And Meters
LCD Display
DF
Flange And Process Connections
½–14 NPT flange adapters
I1
Product Certifications
ATEX Intrinsic Safety
Q4
Calibration And Testing
Calibration Certificate
1199 Remote Diaphragm Seal - 1199WDB3AAEFWK1DB80
1199
Product Series
Remote Diaphragm Seal
W
System Design
Welded Repairable System
D
Seal Structure
Direct Mount Seal
B3
Extension Length
B3 (Extension Length Code) [Unit: Inches]
A
Seal Location
One seal, high pressure side
A
Fill Fluid
200 Silicone (-40 to 205 C)
EFW
Connection Type
Connection Type: EFW
K1
Flange Size & Rating
Flange Size/Rating: K1
DB
Diaphragm & Flange Material
Alloy C-276
80
Capillary Protection
Capillary Protection: 80

Engineering Dimensions

Reliable Partnership with GT-EXIM

As an established industrial supplier, GT-EXIM ensures your procurement efficiency. We leverage our robust supply chain and large-scale stock inventory to offer highly competitive factory pricing and minimized lead times. Every unit supplied is 100% genuine and brand new, packed with heavy-duty export reinforcement to guarantee safe delivery globally. Partner with us for a streamlined, risk-free sourcing experience.

Ready to Start Your Project?

Contact us for a formal quotation and technical data confirmation.

📧 Email: sales@gt-exim.com
💬 WhatsApp: +86 17719526488

Full Configuration Details

Complete Ordering Code:
3051CD3F22A1BS1M5DFI1Q4+1199WDAB3AEFWK1DB80
Transmitter Main Body - 3051CD3F22A1B
3051C
Product Series
Coplanar Pressure Transmitter (Differential, Gage, or Absolute)
D
measurement_type
Differential
3
pressure_ranges
-1000 to +1000 inH2O (-2.48 to +2.48 bar) [3051CD/CG]; 0 to 800 psia (0 to 55.15 bar) [3051CA]
F
transmitter_output
FOUNDATION™ Fieldbus Protocol
2
transmitter_flange_type_and_material
Coplanar / SST / SST
2
isolating_diaphragm
316L SST
A
o_ring
Glass-filled PTFE
1
sensor_fill_fluid
Silicone
B
housing_material
Aluminum / M20 x 1.5
Optionals - S1M5DFI1Q4
S1
Ancillary Assemblies
Assemble to one Rosemount 1199 diaphragm seal
M5
Display And Meters
LCD Display
DF
Flange And Process Connections
½–14 NPT flange adapters
I1
Product Certifications
ATEX Intrinsic Safety
Q4
Calibration And Testing
Calibration Certificate
1199 Remote Diaphragm Seal - 1199WDB3AAEFWK1DB80
1199
Product Series
Remote Diaphragm Seal
W
System Design
Welded Repairable System
D
Seal Structure
Direct Mount Seal
B3
Extension Length
B3 (Extension Length Code) [Unit: Inches]
A
Seal Location
One seal, high pressure side
A
Fill Fluid
200 Silicone (-40 to 205 C)
EFW
Connection Type
Connection Type: EFW
K1
Flange Size & Rating
Flange Size/Rating: K1
DB
Diaphragm & Flange Material
Alloy C-276
80
Capillary Protection
Capillary Protection: 80

Documents