Buy Rosemount 3051CD2F22A1AS2B4K5Q4Q8+1199DCC59AFFW71DB00+1199DCC59AFFW71DB00 Remote Diaphragm Seal – ATEX/FM Certified, Alloy C-276, Fast Delivery, Wholesale

3051CD2F22A1AS2B4K5Q4Q8+1199DCC59AFFW71DB00+1199DCC59AFFW71DB00

The Rosemount 3051CD2F22A1AS2B4K5Q4Q8+1199DCC59AFFW71DB00+1199DCC59AFFW71DB00 is a highly reliable remote diaphragm seal featuring FOUNDATION™ Fieldbus Protocol, designed for demanding industrial applications.

★★★ Gold-Tier Rosemount Supplier in China

  • 复选标记 100% Genuine & Brand New
  • 复选标记 Global Fast Shipping via DHL/FedEx
  • 复选标记 Fast Quotation within 12 Hours
  • 复选标记 1-Year Warranty Guaranteed
SKU: 3051CD2F22A1AS2B4K5Q4Q8+1199DCC59AFFW71DB00+1199DCC59AFFW71DB00 分类: , , 标签: ,

Product Overview

The Rosemount 3051CD2F22A1AS2B4K5Q4Q8+1199DCC59AFFW71DB00+1199DCC59AFFW71DB00 represents the apex of differential pressure measurement for the most corrosive and demanding process environments. This fully configured Remote Diaphragm Seal system integrates a Coplanar™ pressure transmitter with two Alloy C-276 remote seals, engineered to isolate the sensing element from aggressive media. Utilizing a FOUNDATION™ Fieldbus output, this assembly delivers high-resolution digital process data directly to your control network, enabling advanced diagnostics and seamless asset management. The system is specifically designed for applications where process fluid compatibility, high-temperature isolation, and long-term operational stability are non-negotiable.

Key Features & High-End Benefits

Alloy C-276 Material Construction: The wetted diaphragm and seal body are fabricated from Hastelloy® C-276, offering exceptional resistance to pitting, stress-corrosion cracking, and oxidizing agents. This metallurgical choice ensures operational integrity in environments containing chlorides, sulfuric acid, or wet chlorine, drastically reducing lifecycle costs associated with material degradation.
FOUNDATION™ Fieldbus Protocol Integration: The 3051CD transmitter with FOUNDATION Fieldbus output provides full digital communication, including cyclic data, alarm management, and multi-variable measurement capabilities. This enables process optimization through real-time compensation for static pressure and temperature effects, while reducing wiring complexity and installation costs.
Extended Measurement Range & Stability: Capable of measuring differential pressures from -250 to +250 inH2O, with an absolute pressure range of 0 to 150 psia, this system delivers high accuracy across a broad spectrum of flow, level, and pressure applications. The remote seal configuration dampens

Full Configuration Details

Complete Ordering Code:
3051CD2F22A1AS2B4K5Q4Q8+1199DCC59AFFW71DB00+1199DCC59AFFW71DB00
Transmitter Main Body - 3051CD2F22A1A
3051C
Product Series
Coplanar Pressure Transmitter (Differential, Gage, or Absolute)
D
measurement_type
Differential
2
pressure_ranges
-250 to +250 inH2O (-621.60 to +621.60 mbar) [3051CD/CG]; 0 to 150 psia (0 to 10.34 bar) [3051CA]
F
transmitter_output
FOUNDATION™ Fieldbus Protocol
2
transmitter_flange_type_and_material
Coplanar / SST / SST
2
isolating_diaphragm
316L SST
A
o_ring
Glass-filled PTFE
1
sensor_fill_fluid
Silicone
A
housing_material
Aluminum / 1/2-14 NPT
Optionals - S2B4K5Q4Q8
S2
Ancillary Assemblies
Assemble to two Rosemount 1199 seals
B4
Mounting Brackets
SST mounting bracket with SST Bolts
K5
Product Certifications
FM Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2
Q4
Calibration And Testing
Calibration Certificate
Q8
Quality And Material Certificates
Material Traceability Certification per EN 10204 3.1B
1199 Remote Diaphragm Seal - 1199DC59CAFFW71DB00
1199
Product Series
Remote Diaphragm Seal
D
System Design
Tuned-System Assembly
C
Seal Structure
Capillary Seal (Remote Mount)
59
Capillary Length
59 (Capillary Length Code) [Unit: Feet]
C
Seal Location
Two seals, identical configurations
A
Fill Fluid
200 Silicone (-40 to 205 C)
FFW
Connection Type
Flush Flanged Seal
71
Flange Size & Rating
3-in., Class 150
DB
Diaphragm & Flange Material
Alloy C-276
00
Capillary Protection
No capillary protection
1199 Remote Diaphragm Seal - 1199DC59CAFFW71DB00
1199
Product Series
Remote Diaphragm Seal
D
System Design
Tuned-System Assembly
C
Seal Structure
Capillary Seal (Remote Mount)
59
Capillary Length
59 (Capillary Length Code) [Unit: Feet]
C
Seal Location
Two seals, identical configurations
A
Fill Fluid
200 Silicone (-40 to 205 C)
FFW
Connection Type
Flush Flanged Seal
71
Flange Size & Rating
3-in., Class 150
DB
Diaphragm & Flange Material
Alloy C-276
00
Capillary Protection
No capillary protection

Engineering Dimensions

Reliable Partnership with GT-EXIM

As an established industrial supplier, GT-EXIM ensures your procurement efficiency. We leverage our robust supply chain and large-scale stock inventory to offer highly competitive factory pricing and minimized lead times. Every unit supplied is 100% genuine and brand new, packed with heavy-duty export reinforcement to guarantee safe delivery globally. Partner with us for a streamlined, risk-free sourcing experience.

Ready to Start Your Project?

Contact us for a formal quotation and technical data confirmation.

📧 Email: sales@gt-exim.com
💬 WhatsApp: +86 17719526488

Full Configuration Details

Complete Ordering Code:
3051CD2F22A1AS2B4K5Q4Q8+1199DCC59AFFW71DB00+1199DCC59AFFW71DB00
Transmitter Main Body - 3051CD2F22A1A
3051C
Product Series
Coplanar Pressure Transmitter (Differential, Gage, or Absolute)
D
measurement_type
Differential
2
pressure_ranges
-250 to +250 inH2O (-621.60 to +621.60 mbar) [3051CD/CG]; 0 to 150 psia (0 to 10.34 bar) [3051CA]
F
transmitter_output
FOUNDATION™ Fieldbus Protocol
2
transmitter_flange_type_and_material
Coplanar / SST / SST
2
isolating_diaphragm
316L SST
A
o_ring
Glass-filled PTFE
1
sensor_fill_fluid
Silicone
A
housing_material
Aluminum / 1/2-14 NPT
Optionals - S2B4K5Q4Q8
S2
Ancillary Assemblies
Assemble to two Rosemount 1199 seals
B4
Mounting Brackets
SST mounting bracket with SST Bolts
K5
Product Certifications
FM Explosion-Proof, Dust Ignition-proof, Intrinsically Safe, Division 2
Q4
Calibration And Testing
Calibration Certificate
Q8
Quality And Material Certificates
Material Traceability Certification per EN 10204 3.1B
1199 Remote Diaphragm Seal - 1199DC59CAFFW71DB00
1199
Product Series
Remote Diaphragm Seal
D
System Design
Tuned-System Assembly
C
Seal Structure
Capillary Seal (Remote Mount)
59
Capillary Length
59 (Capillary Length Code) [Unit: Feet]
C
Seal Location
Two seals, identical configurations
A
Fill Fluid
200 Silicone (-40 to 205 C)
FFW
Connection Type
Flush Flanged Seal
71
Flange Size & Rating
3-in., Class 150
DB
Diaphragm & Flange Material
Alloy C-276
00
Capillary Protection
No capillary protection
1199 Remote Diaphragm Seal - 1199DC59CAFFW71DB00
1199
Product Series
Remote Diaphragm Seal
D
System Design
Tuned-System Assembly
C
Seal Structure
Capillary Seal (Remote Mount)
59
Capillary Length
59 (Capillary Length Code) [Unit: Feet]
C
Seal Location
Two seals, identical configurations
A
Fill Fluid
200 Silicone (-40 to 205 C)
FFW
Connection Type
Flush Flanged Seal
71
Flange Size & Rating
3-in., Class 150
DB
Diaphragm & Flange Material
Alloy C-276
00
Capillary Protection
No capillary protection

Documents