Buy Rosemount 3051CFPDF005D3H0800D52XpIV2K7HR5 Integral Orifice Flow Meter – Alloy C-276, Integral Manifold, Quick Lead Time, China Manufacturer

3051CFPDF005D3H0800D52XpIV2K7HR5

The Rosemount 3051CFPDF005D3H0800D52XpIV2K7HR5 is a highly reliable integral orifice flow meter featuring Wireless, designed for demanding industrial applications.

★★★ Gold-Tier Rosemount Supplier in China

  • 复选标记 100% Genuine & Brand New
  • 复选标记 Global Fast Shipping via DHL/FedEx
  • 复选标记 Fast Quotation within 12 Hours
  • 复选标记 1-Year Warranty Guaranteed
SKU: 3051CFPDF005D3H0800D52XpIV2K7HR5 分类: , , 标签: ,

Product Overview

The Rosemount 3051CFPDF005D3H0800D52XpIV2K7HR5 Integral Orifice Flow Meter represents a paradigm shift in differential pressure flow measurement for remote and hazardous environments. Designed for operational integrity in the most demanding industrial settings, this device integrates a precision-machined orifice plate with a wireless transmitter, eliminating the need for impulse piping and traditional conduit infrastructure. Engineered for process optimization, it delivers a calibrated measurement range of 0 to 250 inH2O (0 to 621.60 mbar) with exceptional accuracy and repeatability. The use of an advanced engineered polymer housing ensures corrosion resistance and long-term stability, while the absence of conduit entries simplifies installation and reduces maintenance burdens in classified areas. This product is purpose-built for asset-intensive industries requiring reliable, low-power flow data acquisition without compromising safety or performance.

Key Features & High-End Benefits

– **Wireless Output Signal for Remote Monitoring**: The integrated WirelessHART communication protocol eliminates the need for field wiring, reducing installation costs by up to 60% while enabling real-time data access from centralized control rooms. This feature enhances process visibility in hard-to-reach locations, such as pipeline skids or tank farms, without sacrificing data integrity.
– **Engineered Polymer Housing with No Conduit Entries**: The hermetically sealed, non-metallic enclosure provides superior resistance to corrosive atmospheres, moisture ingress, and vibration. By removing conduit entries, the design mitigates potential failure points and simplifies site compliance with explosion-proof and dust-ignition-proof requirements (e.g., Class I, Division 1).
– **Integrated Orifice for Direct Flow Measurement**: The built-in, primary flow element eliminates the need for separate orifice plates, flanges, and impulse lines, reducing leak paths and installation complexity. This integration ensures a tighter measurement uncertainty, typically better than ±0.5% of calibrated

Full Configuration Details

Complete Ordering Code:
3051CFPDF005D3H0800D52XpIV2K7HR5
Transmitter Main Body - 3051CFPDF005D3H0800D52XpI
3051CFP
Product Series
Integral Orifice Flow Meter
D
measurement_type
Differential pressure
F
material_type_and_body
316 SST, enhanced support body
005
line_size
½ in. (15 mm)
D3
process_connection
Pipe ends: flanged, PN100 EN-1092-1 RF, slip-on
H
orifice_plate_material
Alloy C-276
0800
bore_size_option
0.800 in. (20.32 mm) for 1 inch pipe
D5
transmitter_connection_platform
Direct-mount, 5-valve manifold, SST
2
differential_pressure_range
0 - 250 inH2O (0 to 621.60 mbar)
X
transmitter_output
Wireless
p
housing_material
Engineered polymer / No conduit entries
I
transmitter_performance_class
Up to ±1.75% flow rate accuracy
Optionals - V2K7HR5
V2
Comprehensive Options
Radiographic examination
K7
Comprehensive Options
IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
HR5
Software And Configuration
Configured for HART Revision 5

Engineering Dimensions

Reliable Partnership with GT-EXIM

As an established industrial supplier, GT-EXIM ensures your procurement efficiency. We leverage our robust supply chain and large-scale stock inventory to offer highly competitive factory pricing and minimized lead times. Every unit supplied is 100% genuine and brand new, packed with heavy-duty export reinforcement to guarantee safe delivery globally. Partner with us for a streamlined, risk-free sourcing experience.

Ready to Start Your Project?

Contact us for a formal quotation and technical data confirmation.

📧 Email: sales@gt-exim.com
💬 WhatsApp: +86 17719526488

Full Configuration Details

Complete Ordering Code:
3051CFPDF005D3H0800D52XpIV2K7HR5
Transmitter Main Body - 3051CFPDF005D3H0800D52XpI
3051CFP
Product Series
Integral Orifice Flow Meter
D
measurement_type
Differential pressure
F
material_type_and_body
316 SST, enhanced support body
005
line_size
½ in. (15 mm)
D3
process_connection
Pipe ends: flanged, PN100 EN-1092-1 RF, slip-on
H
orifice_plate_material
Alloy C-276
0800
bore_size_option
0.800 in. (20.32 mm) for 1 inch pipe
D5
transmitter_connection_platform
Direct-mount, 5-valve manifold, SST
2
differential_pressure_range
0 - 250 inH2O (0 to 621.60 mbar)
X
transmitter_output
Wireless
p
housing_material
Engineered polymer / No conduit entries
I
transmitter_performance_class
Up to ±1.75% flow rate accuracy
Optionals - V2K7HR5
V2
Comprehensive Options
Radiographic examination
K7
Comprehensive Options
IECEx Flame-proof, Dust Ignition-proof, Intrinsic Safety, and Type n (combination of I7, N7, and E7)
HR5
Software And Configuration
Configured for HART Revision 5

Documents